<LOGO>
FM Transmitter Measurement Report
Created: 2025-08-18 20-55-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 5.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 63 kHz 3945 0,4309
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,00 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 63 kHz MIN: 11 kHz % above 76 kHz: 0,4309 Acquired: 2025/08/18 20.54.08 Total samples: 3945 Equivalent time: 0:03:17 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 5,7 dBr MIN: 4,1 dBr AVE: 5,00 dBr % above 12,2 dBr: 0,0 Last value: 5,2 dBr (2025/08/18 20.54.07) 20.40 20.42 20.44 20.46 20.48 20.50 20.52 20.54 0 2 4 6 Pm [dBr]